fbpx
Select Page

DPS3100D Smart Pressure Transmitter

For Monitoring Hydronic HVAC Systems

Taco DPS sensors monitor the differential pressure in a hydronic HVAC system. As the system operates and sees an increase or decrease in demand, these sensors relay the system pressure changes back to the building management system or VFD to modulate pump speed. Taco offers two models: the DPS629 Differential Pressure Transmitter, designed to meet NEMA 4X (IP66) construction, and the DPS3100D Smart Pressure Transmitter, with a 100:1 turn downrange that allows the smart transmitter to be configured to fit any application.

DPS3100D

The Taco DPS3100D Smart Pressure Transmitter is a microprocessor-based high-performance transmitter that has flexible pressure calibration, push-button configuration and programmable using HART® Communication. The DPS3100D is capable of being configured for differential pressure or level applications with the zero and span buttons. A field calibrator is not required for configuration. The transmitter software compensates for thermal effects, improving performance. EEPROM stores configuration settings and stores sensor correction coefficients in the event of shutdowns or power loss. The DPS3100D is FM approved for use in hazardous (classified) locations. The 100:1 range-ability allows the smart transmitter to be configured to fit any application.
HART® is a registered trademark of Hart Communication Foundation.

Catalog    
Instruction Sheet    
Submittal Data    
Find your Taco Sales Representative
Click below to get in touch with your local Taco supplier:
Find a Rep
We’re Here to Help
Support is only a click away! Our dedicated customer service and tech support teams are waiting to hear from you.
Support
Performance Data

Accuracy: ±0.075% FS (@ 20°C)
Range Ability: 100:1 Turn Down
Stability: ±0.125% FSO/Year
Temperature Limits: Process -40 to 248°F (-40 to 120°C) Ambient – without LCD -40 to 185°F (-40 to 85°C) – with LCD -22 to 176°F (-30 to 80°C)
Max. Pressure Range: -14.5 to 2000 PSI, Burst Pressure: 10,000 PSI
Thermal Effect: ±0.125% span/32°C
Power Requirements: 11.9 to 45 VDC
Output Signal: 4 to 20 mA

Features
  • Configurable Using Zero/Span Buttons (No Calibrator Required)
  • Range-ability (100:1)
  • High Accuracy (±0.075%)
  • Automatic Sensor Temperature Compensation
  • Fail-Mode Process Function
Applications
  • Hydronic HVAC Systems
  • Flow Measurement
  • Level Monitoring
  • Filter or Pump Differential Pressure
  • Critical Process Monitoring
Accessories

DPS3100A-1F (Flanged 3-Valve Block Manifold)

Models & Related Documents

Pin It on Pinterest